Below are the steps to take when using a hydraulic sausage filler for the first time, here are some essential tips to consider. Ensure the machine is placed steadily on the ground and the power supply is connected correctly, paying attention to the positive and negative connections. After no-load operation, check whether the machine is […]
To operate the hydraulic sausage machine, begin by adding No. 46 oil to the cylinder and connecting it to a suitable power source. Confirm that the machine rotates forward and backward before starting the process. Once the machine is ready, insert the mixed meat stuffing and press the drop button on the control panel. The […]
After each use, either rinse any remaining materials thoroughly or disassemble and clean any inaccessible areas. If the machine’s noise level increases, it indicates either insufficient oil in the gears or worn-out parts, requiring an oil refill or part replacement. If the machine isn’t used daily, clean it after each use and seal it properly […]
One reason could be a blocked vacuum tube in the sausage enema machine. Simply remove the vacuum tube and clean it to resolve the problem. Another reason may be a clogged vacuum pump filter. The solution is to either clean or replace the vacuum pump filter. If the machine is filling thick materials, it may […]
The power supply might not be connected properly. It could be due to a blown fuse, which requires replacement.
This issue is primarily caused by the cylinder pressure regulator’s low pressure adjustment on the enema machine. To resolve this problem, you need to increase the pressure regulating gas’s working pressure on the cylinder.
What is the reason behind the spiral feeding transmission device of the hydraulic sausage filler machine’s inflexible rotation?